Cabinetry
Pipe
Stainless Steel Sinks
Faucets
China
Vanity Tops
Range Tops
PLASTIC PIPES << BACK

Click here to download the Plastic Pipe Product Catalog & Product Specifications
Click here to download the Material Safety Data Sheet
Download ADOBE ACROBAT PDF Reader

TBA is one of the worlds largest manufacturers of sewer pipe in the industry. Our state of the art facility located in Louisville, KY is not only one of the largest sewer gasket manufacturing companies but it is also a leading source for your sch40, dwv, and potable water pipe as well.
We also manufacture and distribute coex, cellular core, conduit, victaulic groove pipe, direct burial conduit along with cpvc and rolled coil pipe as well as the necessary fittings and adhesives to finish the project.
We are able to deliver on our own fleet of trucks as well as common carrier. TBA pipe can also be shipped along with the multitude of plumbing and electrical products we are able to offer, making TBA your best choice in product and service.
POWER & COMMUNICATIONS
PVC PLASTIC UTILITY DUCT


TBA Utilities Duct is made of PVC homopolymer material with a cell classification of 12264 or 12254, as defined in ASTM standard D 1784. TBA DUCT pipe is manufactured in accordance with the following standards:

• American Society for Testing and Materials (ASTM) F-512
• National Electrical Manufacturers Association (NEMA) TC-6 & TC-8
Properties:
• Non Magnetic
• Easy Installation, assuring a safe integral systems
• Corrosion Resistant
• Superior water proof assembly joints
• Excellent Impact Resistant
• Stiffness factor : 10% above the standards
• Designed to meet 90 C conductors / wires
• Modulus of Elasticity : 400,000 PSI or 500,000 PSI (depending on material cell class)

TYPE DB-60 (DIRECT BURIAL) TC-6
DESIGNED FOR DIRECT BURIAL UNDERGROUND WITHOUT CONCRETE ENCASEMENT
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
2" 401-0229   20' BE 2.375 2.225 0.060 34 2800' 966
3" 401-0230   20' BE 3.500 3.286 0.092 72 1760' 1297
4" 401-0150   20' BE 4.500 4.228 0.121 119 1140' 1389
5" 401-2087   20' BE 5.563 5.229 0.152 183 760' 1416
6" 401-2088   20' BE 6.625 6.231 0.182 258 520' 1368

TYPE DB-120 (DIRECT BURIAL) TC-8
DESIGNED FOR DIRECT BURIAL UNDERGROUND WITHOUT CONCRETE ENCASEMENT
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
2" 401-0374   20' BE 2.375 2.191 0.077 42 2800' 1195
3" 401-1847   20' BE 3.500 3.234 0.118 90 1760' 1618
4" 401-1848   20' BE 4.500 4.162 0.154 147 1140' 1713
5" 401-2155   20' BE 5.563 5.151 0.191 230 760' 1786
6" 401-2156   20' BE 6.625 6.141 0.227 258 520' 1675

TYPE EB-20 (ENCASED BURIAL) TC-6
DESIGNED FOR UNDERGROUND CONCRETE ENCASEMENT BURIAL
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
2" 401-2090   20' BE 2.375 2.225 0.060 33 2800' 953
3" 401-2091   20' BE 3.500 3.348 0.061 52 1760' 928
4" 401-2092   20' BE 4.500 4.306 0.082 88 1140' 1020
5" 401-0375   20' BE 5.563 5.327 0.103 130 760' 1011
6" 401-2089   20' BE 6.625 6.345 0.125 184 520' 976

TYPE EB-35 (ENCASED BURIAL) TC-6
DESIGNED FOR UNDERGROUND CONCRETE ENCASEMENT BURIAL
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
2"    20' BE 2.375 2.225 0.060 33 2800' 953
3"    20' BE 3.500 3.318 0.076 58 1760' 928
4"    20' BE 4.500 4.270 0.100 101 1140' 1020
5"    20' BE 5.563 5.281 0.126 153 760' 1011
6"    20' BE 6.625 6.291 0.152 220 520' 976

Standard DB/EB conduit is normally 20' in lay length with one belled end. Customized specifications may be available upon request.


 PVC TELEPHONE DUCT

Type B (Designed for Concrete Encased Applications) TC-10
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
4"    20' BE 4.350 4.148 0.091 92 1140' 1049

Type C (Designed for Direct Burial Applications) TC-10
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
4"    20' BE 4.350 4.024 0.148 146 1140' 1669

Type D (Designed for Exposed Applications)
TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
4"    20' BE 4.350 4.024 0.148 149 1140' 1702

Standard Telephone Duct normally 20' in lay length with one belled end. Customized specifications may be available upon request.




RIGID NONMETALLIC CONDUIT - SCHEDULE 40
SCHEDULE 40 RIGID PVC CONDUIT ( HEAVY WALL)
LISTED FOR ABOVE GROUND AND UNDER GROUND APPLICATIONS


PVC Conduit 1 PVC Conduit 2 PVC Conduit 3

• Sun light Resistant
• Rated for 90 C conductors / wires
• Corrosion Resistant
• Superior weathering characteristics
• Excellent Impact Resistance Properties
• Easy Installation, assuring a safe integral systems

TRADE
SIZE
PART
NUMBER
DESCRIPTION
OF PIPE
AVERAGE
O.D. (in.)
MIN AVE
I.D. (in.)
MINIMUM
WALL (in.)
WEIGHT
PER 100' (lbs.)
STD. CRATE QTY.
LAY LENGTH (ft) NET (lbs)
1/2"005416 01   10' BE 0.840 0.578 0.109 16 6000 984
3/4"005417 01   10' BE 1.050 0.78 0.113 22 4400 959
1" 005418 01   10' BE 1.315 1.004 0.133 32 3600 1163
11/4" 005419 01   10' BE 1.660 1.335 0.140 44 3300 1442
11/2" 005420 01   10' BE 1.900 1.564 0.145 52 2250 1172
2" 005421 01   10' BE 2.375 2.021 0.154 70 1400 979
2" 006749 01   20' BE 2.375 2.021 0.154 70 2800 1957
21/2" 005590 01   10' BE 2.875 2.424 0.203 110 930 1026
3" 005447 01   10' BE 3.500 3.008 0.216 144 880 1266
3" 006750 01   20' BE 3.500 3.008 0.216 144 1760 2533
31/2" 461-0384 01   10' BE 4.000 3.486 0.226 174 630 1095
4" 005448 01   10' BE 4.500 3.961 0.237 206 570 1175
4" 461-1528 01   20' BE 4.500 3.961 0.237 206 1140 2351
5" 461-1973 01   10' BE 5.563 4.975 0.258 280 380 1064
6" 461-0364 01   10' BE 6.625 5.986 0.280 363 260 943

Standard DB/EB conduit is normally 20' in lay length with one belled end. Customized specifications may be available upon request.

TBA nonmetallic Schedule 40 Conduits are complying with the following Standards:
• Underwriters Laboratory, Inc. (UL) UL 651
• National Electrical Manufacturers Association (NEMA) TC-2

Back to Top